NURS 2007 Assignment: Clinical Guidelines For Diabetes Monitoring

NURS 2007 Assignment: Clinical Guidelines For Diabetes Monitoring

NURS 2007 Assignment: Clinical Guidelines For Diabetes Monitoring

KINDLY ORDER NOW FOR A CUSTOM-WRITTEN AND PLAGIARISM-FREE PAPER

Questions:

1. Critique your 2 clinical practice guidelines using the AGREE 11 tool
2. Discuss (using evidence) why you believe one of these policies, or procedures, or protocols is better than the other
3. Focussing on the differences; suggest possible reasons why this might be the case – eg: cultural differences , a new organisation as opposed to an old one, size of the
organisation, relevance of the policy to the organisations client base, resources available to the organisation , etc

NURS 2007 Assignment: Clinical Guidelines For Diabetes Monitoring Sample Draft Solution:

Introduction

The two clinical practice guidelines for Diabetes Monitoring are Self-Monitoring of Blood Glucose (SMBG) and Continuous Glucose Monitoring Systems (CGM). SMBG applies Flash devices to check for the glucose levels in a diabetic individual (Parsons et al., 2017). The patient wears the flash device for fourteen days to monitor the diabetic condition. The diabetic client flashes the sensor on the device to get the glucose readings. The device records the levels of glucose at the intervals of fifteen minutes (Overland et al., 2014). Specialists recommend that the patients wear the device for twenty-four hours to monitor their diabetic states. The method is useful for both type one and two diabetes mellitus.

CGM gauges the concentration of glucose in the fluids at the interstitial space (Bell et al., 2015). The real-time CGM device displays time-to-time glucose levels. Additionally, the method provides an alarm notification if the levels of glucose shoot above or below the normal concentrations. However, a blinded CGM device records the glucose concentrations but fails to display the readings. The caregiver has to download the readings from the blinded device to view and analyze the results from a computer (Boom et al., 2014). This paper will critique the two guidelines for diabetes monitoring using the AGREE II tool. The write-up will also explain why CGM is better than SMBG and explain the differences between the two directions.

Sample Disclaimer
Ulcius: Your reliable nursing solution partner. KINDLY ORDER NOW FOR A CUSTOM-WRITTEN AND PLAGIARISM-FREE PAPER

Critiquing The Two Guidelines Using The AGREE II Tool

The score sheet for the SMBG guidelines is found in the first appendix. The authors of the guidelines have described the objectives of the protocols. Additionally, the health question is specific to the target population who are diabetic patients. The individuals who developed the guidelines are distinguished doctors and professors in the medical field. The investigators requested the preference and views of the diabetic patients before writing the procedures. The protocols patients with type one and two diabetes. The authors used information in the COCHRANE library, and Pub MED sources to develop an evidence-based write-up.

The researchers used sources from the year 2010 to 2013 with information on the clinical guidelines for diabetes monitoring. The paper also describes the strengths and limitation of the study. One of the advantages is that it covers both the disadvantages and disadvantages of SMBG. However, the boundaries of the research include the fact that the number of participants is few; hence limiting its scope. The authors are also evident in the recommendations, benefits, and disadvantages of the research. The document is peer-reviewed and indicates the procedures of updating the content. The above qualifications allow caregivers to apply the report in caring for diabetic patients. However, the authors fail to record competing interests. Therefore, the guideline is of high quality and I would recommend caregivers to use it.

The score sheet for CGM is found in the second appendix. The authors of the protocol have indicated its scope and purpose, as they have recorded the objectives, health questions, and target population. The authors have relevant academic qualifications, and they also consider the views of diabetic patients. The development of the procedures is thorough as the investigators indicate relevant details of a research paper.

The researchers are clear on their recommendations. They also offer different options for diabetes management. The evidence from the guidelines is applicable as it indicates the barriers and facilitators of the protocols among other details. The CGM guideline advices the diabetic patients on how to apply the recommendations in real life; however, it does not indicate auditing criteria. Additionally, there is no indication on whether the funding body has influenced the contents of the protocol or otherwise. The write-up had a recorder and addressed the competing interests. Therefore, I highly recommend the application of the CGM guidelines.

Advantages Of CGM Over SMBG Guidelines For Diabetes Monitoring

The CGM devices like the real-time equipment detect and record the glucose levels after every five minutes. Therefore, the system indicates the current trends in the fluctuation of diabetes status in the patient (Rodbard, 2016). However, the SMBG devices like the flash indicator do not display a continuous reading of the sugar levels. The patient can take appropriate measures at each reading time. The CGM devices provide the high and low glucose alarms, a parameter that is absent in the SMBG guidelines. The diabetic client stays updated of the readings throughout the day as opposed to SMBG that provides intermittent data. Furthermore, CGM guidelines are appropriate for individuals who are eager to study the trends of blood sugar fluctuations (Taylor, Thompson, and Brinkworth, 2018). The patient ties the device around the arm as opposed to SMBG that requires the clients to prick their fingers before taking the readings.

Patients find it easy to monitor their blood sugar levels during the day using the CGM guidelines. However, clients using the SMBG can only check the standards of their blood sugar when they flash the sensor (Ancona et al., 2017). The SMBG protocol makes it difficult to monitor glucose levels; since it involves numerous finger-stick examinations. The built-in alarm in the CGM systems enables the users to have tight control over their levels of blood glucose. Recent research has indicated that CGM decreases the levels of A1C in children and adults (Liberman et al., 2016). The protocol is also ideal with individuals who lack CSII but have type diabetes type one. The Real-time CGM measurement saves the time for hypoglycemic examinations. The protocol also suits pregnant women who are having either type two or one diabetes. Diabetes patients should wear the CGM devices for an extended period to ensure credible, accurate, and useful results.

CGM protocols enable users to study both short and long-term parameters in their blood sugar levels. However, the intermittent nature of the SMBG disrupts the investigation of such trends (Cheng et al., 2018). Diabetic patients should wear the CGM devices at all times including when they are asleep. On the other hand, patients can only monitor their diabetic status using the flash device when they are awake. Therefore, patients using real-time detectors can study blood glucose fluctuations when they are at rest. During meal times, the CGM devices remain around the arms or wrists of the diabetic clients. However, patients who are conducting a self-monitoring process cannot eat and at the same time measure their levels of blood glucose (Holmes-Truscott et al., 2016). Therefore, CGM enables users to study their diabetic status between meals. The continuous glucose monitoring devices also allow for patients to monitor their blood sugar levels when conducting and after various activities.

During physical exercise, a diabetic patient is likely to experience many lows in the blood sugar levels. The CGM guidelines enable the patient to detect the point at which the lows begin (Furler et al., 2018). Additionally, the system records the time that the blood sugar remains at the low levels. However, The SMBG devices cannot record and maintain such essential data. The knowledge from the continuous glucose monitoring prepares the patient for any changes during physical exercise (Gray, 2017). The patient can then take an appropriate action to prevent the drop at the time of activity. An example of the remedies towards the blood glucose low is adjusting the insulin injections. The patient can also change the snack after, during, or before the exercise. Diabetic patients always record low sugar levels; since the muscles convert glycogen into energy during strenuous activities. After physical exercise, the sugar levels drop even further thereby calling for a remedy.

Another advantage of the CGM over the SMBG is that the former can monitor and recorder the blood sugar fluctuations during meals. Diabetic patients usually record an elevated amount of glucose after meals (Carolan, Holman, and Ferrari, 2015). The CGM machine allows the patient to check the severity and timing of post-meal sugar spikes. The valuable data assist patients in preparing and managing the alterations before and after meals. The patient can evaluate and find out which meals result in a high shot in blood glucose than the others. Examples of foods that raise the readings of the continuous glucose monitoring devices are carbohydrate-rich meals.

KINDLY ORDER NOW FOR A CUSTOM-WRITTEN AND PLAGIARISM-FREE SOLUTION

Incomplete …